Page 102 - Fall 2024 EDM Today
P. 102
EDM Today Magazine EDM Today Magazine EDM Today Magazine
EDM Today Magazine EDM Today Magazine EDM Today Magazine
works very well. While the probe is out, the accessory
[Editor’s note: EDM Today would like to welcome Tom
VanValkenburgh of TommyV EDM. Tom specializes in
pump should turn off, and you should receive a “clean
service on Fanuc Wire EDMs. He has 28 years of service
tank empty alarm.” Please check the probe for algae;
it will be black and slimy. If you have algae, I
experience. Just within the last year, Tom has struck out
recommend buying an algae-killing light for ponds,
on his own and formed TommyV EDM. We wish Tom
which can be found online, and placing it in a
great success in his service business and look forward
clean tank.
to more submissions.]
4) While the probe is out and the accessory pump is off
EDM Today Magazine EDM Today Magazine EDM Today Magazine
(put the machine into E-Stop if you are unsure), please
check and clean your Wye strainer(s). A dirty Wye
strainer will cause poor fl ow to the resin bottle, and it
Q: The resistance lamp is fl ashing and is lower than the
will not be able to bring the resistivity back up. I have
set value of 5.0, or I have a warning/alarm message that
been on several service calls in which a customer has
changed out several resin bottles, but the resistivity
says “2066 Exchange the ion resin.” Do I need to change
the bottle?
won’t come up, and it was due to a dirty Wye strainer –
see Figure 2.
A: You might think the answer is yes, but it could be
premature. Before changing the bottle, I recommend the
following checks:
1) Have you recently added make-up water? Tap water
EDM Today Magazine EDM Today Magazine EDM Today Magazine
will lower the water’s resistance. Have you recently
changed the fi lters? Some fi lters are washed with a
detergent that will lower the water’s resistance.
2) If possible, check the output of the resin bottle. If the
resistivity is lower than the set value, water should
steadily fl ow out of the bottle, and fi ll a gallon-sized
bucket in around 30 seconds. I would then check the
Figure 2 Wye Strainer
water in the clean bucket with a meter like an “Aquapro”
AP-2 meter, which can be
found online for less than 5) If you were able to check the resin bottle output with a
meter, and it was over 16 micro Siemens, then change it
$40. A new bottle should
EDM Today Magazine EDM Today Magazine EDM Today Magazine
out. If you cannot check it with a meter, but your
have an output of close to
strainers are clean and you haven’t added make-up
0 micro Siemens (over
water recently, then change the bottle. Often a bad
1,000,000 ohms), but a bottle
bottle will also make the water smell a little fi shy.
is bad if the water measures
over 16 micro Siemens
(about 62,000 ohms).
Q: What is the purpose of the Deionizing (DI) bottle?
3) Then check and clean the
A: Water is a universal solvent that allows the ion
resistivity probe – see Figure
1. Always be sure to fl oss
Contrary to popular belief, water does not conduct
between the tines with a rag Figure 1 Resistivity Probe particles to distribute evenly, and it is also an insulator.
electricity, but rather the ions in the water do. Because wa-
or Scotch Brite. A mild acid
ter is an insulator and a universal solvent, we can control
EDM Today Magazine EDM Today Magazine EDM Today, Fall 2024 Issue
EDM Today Magazine
like Beaver Lime Go Green
how well the water allows electricity to pass through it.
100